1

Type mumps -dir at the Unix prompt to enter the M programmer’s environment. Then, at the prompt in M, type SET DUZ=1 DO Q^DI.

$ mumps -dir
> SET DUZ=1 D Q^DI

VA FileMan 22.2


Select OPTION: _

2

At the Select OPTION prompt, you can type EN and hit enter, and the option will be completed for you:

Select OPTION: ENTER OR EDIT FILE ENTRIES


Input to what File: SAMI SITE// _

3

If the Input to what file prompt shows the value SAMI SITE, you can hit enter; if not, type SAMI SITE and hit enter:

Input to what File: SAMI SITE//           ([n] entries)

EDIT WHICH FIELD: ALL// _

Here, [n] will be some number that corresponds to your site.

4

At the EDIT WHICH FIELD prompt, hit enter.

EDIT WHICH FIELD: ALL// _

5

At the SAMI SITE prompt, type in the first few letters of a site name. For example, you can type in ZZZTOG, and if your facility list is the same as ours, it will look like this:

SAMI SITE: ZZZTOGUS STNB    ME  STNB  4029AF   INACTIVE

Note that you must choose one of the items on the existing list of facilities. If you need to see the complete (and possibly long list), you can type ?? (as of this writing, a list of about 300 sites will appear). You can choose to enter if you want to see more sites, or you can hit ^ if you are ready to exit the list and put in the first few letters of a site name. Note also that it doesn’t really matter which one you select if you’re on a test system.

6

You’ll be prompted with something like this:

Are you adding 'ZZZTOGUS STNB' as a new SAMI SITE (the [nth])? No// _

where [nth] is an ordinal number representing the number of SAMI sites that will exist if you add this one. Type Y and press enter.

7

You will be given a series of prompts. SYMBOL will be a three-letter abbreviation for the test site (you will need to come up with an abbreviation). ACTIVE will be Y for Yes. DEFAULT PARAMETERS will be VHA, and there is no additional configuration necessary for the Select PARM prompt, so you can hit enter.

SYMBOL: TGS
ACTIVE: Y  YES
DEFAULT PARAMETERS: VHA
Select PARM:


Select SAMI SITE: _

8

Hit enter at the Select SAMI SITE to get out, or add the beginning letters of a new facility to create another site.

9

When the Select OPTION: prompt reappears, hit enter.

10

Finally, when you get the M prompt again, type "H" and hit enter to exit M.